Vertical sump slurry pump
VA vertical cantilever arrangement places the pump head in the sump for mine and coal-preparation duties, without a shaft seal or seal-water requirement.

01 / CONSTRUCTION
DESIGN FOLLOWS DUTY
- Configuration
- Single-stage, single-suction vertical cantilever centrifugal; not a fully submersible motor pump
- Speed range
- 400–2200 r/min
- Published power range
- 15–200 kW
- Wet-end materials
- PG-V: high-chrome wear-resistant castings; PG-V-R: rubber wetted parts
- Shaft sealing
- Sealless shaft arrangement; no seal water
- Installation & drive
- Grease-lubricated bearings; direct or belt drive
01Immersed pump head, bearings above the sump
02Metal and rubber wetted configurations
03Optional suction extension pipe
02 / CLEAR-WATER REFERENCES
READ THE DATA
KEEP THE CONTEXT
| Model | Material | Q m³/h | H m | n r/min | Max. powerkW | η % | NPSH m |
|---|---|---|---|---|---|---|---|
| PG-V-01 | M | 19.44–43.2 | 3.5–28 | 1000–2200 | 15 | 38 | — |
| PG-V-02 | M | 23.4–87.12 | 5.5–31.5 | 700–1500 | 30 | 51 | — |
| PG-V-03 | M | 54–289 | 5–37 | 500–1200 | 75 | 56 | — |
| PG-V-04 | M | 261–1089 | 7.5–33.5 | 400–750 | 200 | 60 | — |
4 models
NPSH is not provided for these selected rows and is shown as “—”. Confirm the connection dimensions and immersion length before ordering.
Q: flow; H: head; n: speed; η: efficiency. M denotes the catalog metal code. “—” means unavailable. Maximum power is not absorbed duty power; The high-head, vertical and gravel series list it maximum belt-drive power. Rows are not complete curves. Apply slurry corrections, cavitation checks and motor sizing.
- Flow, head and system curve
- Density, concentration and particle distribution
- Temperature, pH and material compatibility
- Available NPSH, seal water and installation space
Is a vertical sump pump the same as a submersible pump?+
No. This family immerses the pump head while its motor and bearings remain above the liquid.