High-head slurry pump
MA single-stage, double-casing horizontal design for high-head, lower-flow and concentrated abrasive slurry duties.

01 / CONSTRUCTION
DESIGN FOLLOWS DUTY
- Configuration
- Single-stage, single-suction, cantilever, double-casing horizontal centrifugal
- Speed range
- 450–2200 r/min
- Published power range
- 30–1200 kW
- Wet-end materials
- Wear-resistant high-chrome alloy; rubber configurations require duty confirmation
- Shaft sealing
- Packing / expeller / mechanical seal
- Installation & drive
- Discharge orientation at 45° intervals; grease or oil lubrication options
01Ribbed ductile-iron outer casing
02Front and rear auxiliary impeller vanes
03Large-diameter, short-overhang shaft
02 / CLEAR-WATER REFERENCES
READ THE DATA
KEEP THE CONTEXT
| Model | Material | Q m³/h | H m | n r/min | Max. powerkW | η % | NPSH m |
|---|---|---|---|---|---|---|---|
| PG-M-01 | M | 16.2–34.2 | 25–92 | 1400–2200 | 30 | 20 | 2–5.5 |
| PG-M-02 | M | 68.4–136.8 | 25–87 | 850–1400 | 60 | 47 | 3–7.5 |
| PG-M-03 | M | 126–252 | 12–97 | 600–1400 | 120 | 50 | 2–5 |
| PG-M-04 | M | 324–720 | 30–98 | 600–1000 | 560 | 64 | 3–8 |
| PG-M-05 | M | 576–1152 | 32–95 | 450–725 | 1200 | 65 | 6–10 |
5 models
The family summary and individual model sizes may differ. Confirm actual flange dimensions against the approved technical drawings.
Q: flow; H: head; n: speed; η: efficiency. M denotes the catalog metal code. “—” means unavailable. Maximum power is not absorbed duty power; The high-head, vertical and gravel series list it maximum belt-drive power. Rows are not complete curves. Apply slurry corrections, cavitation checks and motor sizing.
- Flow, head and system curve
- Density, concentration and particle distribution
- Temperature, pH and material compatibility
- Available NPSH, seal water and installation space
Are 98 m and 1152 m³/h available simultaneously?+
Family maxima do not define one operating point. Check the model, speed and performance curve.